Isolated analog programming mode (isol) – AMETEK XG Family Programmable DC User Manual

Page 120

Advertising
background image



Analog

Programming (APG) and Isolated Analog Programming (ISOL)

4-20

M370430-01 Rev E

Isolated Analog Programming Mode (ISOL)

See “Rear Panel Connectors on 850 Watt Models” on page 1-7 “Rear
Panel Connectors on 1500 and 1700 Watt Models” on page 1-9 for more
details about connections.

AUX Output and Isolated Analog Programming (ISOL) Connector

The AUX Output and Isolated Analog Programming (ISOL) Connector
is a 15-pin female DSUB connector. See Figure 4-10. All pins on this
connector are electrically isolated from the output of the power supply.

The AUX Output and ISOL Connector provides access to the following
functions:

Function

XG1500 and 1700

XG850

Auxiliary +5 V and +15 V outputs

standard

standard

OUTPUT ENABLE Aux

standard

standard

Power On Status (output)

optional

standard

SD—Shutdown (input)

standard

standard

Interlock

standard

standard

ISOL programming and monitoring

optional

standard

Figure 4-10 AUX Output and ISOL Connector Pinout

IS_VOL_PR_V

IS_VOL_PR_C
UR

IS_MON_VOL

AUX1 (+5V)

S_MON_CUR

INTER_LOCK_1

INTER_LOCK_2

MAIN_PS_GOO

D

SD (Shutdown Main O/P)

AUX2 (+15V)

ISO_VOL_RES
_PR

COM_ISOLATE
D

ISO_CUR_RES_P
R

AUX1_&_AUX2
_On/Off

COM_ISOLATE
D

Advertising