To access the tracking mode for entering voltage and current:

1.

Select the VOLTS or AMPS position on the 9-position mode
control. If the set point is blinking, the unit is in coarse
tracking mode.

•

When the VOLTS mode is selected, the voltage set point will
blink in the output voltage display.

•

When the AMPS mode is selected, the current set point will
blink in the output current display.

2.

Use the rotary Adjust/Enter control to adjust the set point.
Note that there is an activity time out (see Normal Display
Mode and Inactivity Timeout on page 3-6).

The adjustments you make to the set point affect the opposing
output value (voltage when in AMPS mode or current when in
VOLTS mode), which will update in the non-blinking display.

3.

Press the rotary Adjust/Enter control to enter fine adjust
tracking mode.

The set point blinks faster when the unit is in fine adjust tracking
mode.

4.

Use the rotary Adjust/Enter control to fine tune the set point.

5.

Once the set point has been selected, press the rotary
Adjust/Enter control to exit tracking mode and return to
normal display mode.

To access the select and set entry mode for the voltage and current
set points:

1.

Select VOLTS or AMPS position on the 9-position mode
control.

2.

Press the rotary Adjust/Enter control three times in
succession to enter coarse Pre-Set Adjustment.

3.

Press the rotary Adjust/Enter control one more time to enter
fine Pre-Set Adjustment.

4.

Press the rotary Adjust/Enter control once again to set the
value.

The units can also timeout (adjustable) to exit the menu. Once
Pre-Set Mode is entered, CrPU or FnPU will appear in the voltage
display.