Resetting the Power Supply

The reset is used to clear the parameters to the factory default values.

Soft Reset

The soft reset is used to set the parameters (see

Table 3-9

) to the default

values, but it does not reset the calibration constants

To perform a soft reset:

1.

Turn the power supply to Off then On.

When the unit is powering on,

is displayed on the

output voltage and current displays.

2.

Press the key combination of both OUTPUT ENABLE Main

button and OUTPUT ENABLE Aux button and hold
continuously for 3 seconds in order to execute.

If the flash fail alarm triggers, it is also possible to reset the power
supply. The front panel should display

.

3.

Once a reset has been triggered, the output voltage display

shows

for 1 second.

The model number will be displayed for 1 second and then return
to normal mode.

After executing a reset, the power supply's settings are restored to the
default settings but retain the calibration data. Table 3-9 lists the default
settings.

Table 3-9 Power Supply Default Settings

Parameter

Setting

Address

1

Data rate (Kbps)

9.6

Communication mode

RS-232

Vout setting

0 V

Iout setting

0 A

Output

Off

AUX Out

Off

Trigger

Off

Ext. On/Off Polarity

Negative

Auto start mode

Off

AUX Auto start mode

Off

OVP

Maximum

UVP

0 V

Foldback trigger

None

Foldback delay

0.5 s

Current Share Mode

Controller