Local lockout, Enabling local lockout, Disabling local lockout – AMETEK XG Family Programmable DC User Manual

Page 87

Advertising
background image



Local

Operation

M370430-01 Rev E

3-41

3

Local Lockout

Local lockout is a feature that allows the front panel to be locked so that
accidental button presses are ignored. This feature is often used to
lockout the front panel when you are controlling the power supply from
a remote location. When in local lockout mode, the front panel will
display

Loc whenever a button is pressed or a knob is turned.

Enabling Local Lockout

To enable local lockout:

1.

Turn the 9-position mode control to the PGM position or
press the rotary Adjust/Enter control if the control knob is
already at the PGM position.

The display will show

in the output voltage display and the

selected remote interface in the output current display.

2.

Turn the rotary Adjust/Enter control until the display shows

.

3.

Press the rotary Adjust/Enter control.

4.

Turn the rotary Adjust/Enter control until the display shows

.

5.

Press the rotary Adjust/Enter control. Local lockout has been

enabled.

The SCPI command (s) for these instructions are:

[:]SYSTem:REMote:STATe

Disabling Local Lockout

To disable local lockout:

1.

Turn the 9-position mode control to the PGM position or
press the rotary Adjust/Enter control if the control knob is
already at the PGM position.

The display will show

in the output voltage display and the

selected remote interface in the output current display.

2.

Turn the rotary Adjust/Enter control until the display shows

.

3.

Press the rotary Adjust/Enter control.

Local lockout will be disabled after power-cycling the power
supply.

The SCPI command (s) for these instructions are:

[:]SYSTem[<channel(s)>]:REMote:STATe

Advertising
This manual is related to the following products: