Using the ametek ethernet test utility – AMETEK XG Family Programmable DC User Manual

Page 234

Advertising
background image



Communications

Options

6-28

M370430-01 Rev E

Using the AMETEK Ethernet Test Utility

In order to use the AMETEK Ethernet Test Utility, its Host and
Port fields need to be properly set. The Host field should be set to
the power supply’s IP Address. The Port field should be set to the
power supply’s port field (unless the port has been changed, it
defaults to 5025.) The AMETEK LXI Discovery Browser may be
useful in this step to determine the power supply’s IP Address. For
example, the following diagram shows the AMETEK LXI Web
Browser on the left, and the parameters properly filled out on
AMETEK Ethernet Test Utility on the right.

In this case, the AMETEK LXI Discovery Browser was used to
locate the power supply and determine that its address is at
192.168.1.101. This address was entered into the HOST field of
the EnetTest Utility.