Caution: equipment damage – AMETEK XG Family Programmable DC User Manual

Page 94

Advertising
background image



Local

Operation

3-48

M370430-01 Rev E

Connecting to the Load in Remote Sensing Mode

Connect the negative (-) output terminal of one power supply to the
positive (+) output terminal of the next power supply. The more
positive supply's positive sense line should connect to the positive
terminal of the load (or distribution point). Its return sense line
should connect to the connection between the two units at the same
spot as the negative supply's positive sense line. The return sense
line of the negative supply should be connected to the return of the
load. See Figure 3-6.

CAUTION: Equipment damage

Do not connect sense lines through relays.

Figure 3-6

Load Connections in Remote Sensing Mode