Calibration

and Troubleshooting

7-26

M370430-01 Rev E

Emergency Shutdown

In an emergency, carry out these steps:

1.

Shut the power supply OFF immediately.

2.

Disconnect the mains supply.

3.

Disconnect the power supply from the load.

Unusual or Erratic Operation

If the power supply displays any unusual or erratic operation,
follow these steps:

1.

Shut the power supply OFF immediately.

2.

Disconnect the power supply from the load and external

programming.

3.

Test the power supply with no load, running the tests in “Step

5: Performing Functional Tests” on page 2-10.

4.

If the tests show that the power supply is functioning

normally, check all load, programming, and monitoring
connections and circuits.

5.

Check the AC input for correct voltage and frequency.

If the problem is not solved after you have followed this procedure, or if
the unit fails to operate correctly upon retesting, call your service
technician.