background image



Local

Operation

M370430-01 Rev E

3-37

3

Power On Status Signal

Power On Status signal indicates a fault condition in the power supply.
Power On Status signal is a TTL output signal at Pin J2.13 with
reference to COM ISOLATED (Pin J2.2 or Pin J2.6).

During normal operation, the Power On Status signal will be high. If the
output is disabled for any reason, the Power On Status signal will go
low.

The following conditions will set the Power On Status to a low level:

AC fail

Current Loop Protection

Over Voltage Protection (OVP)

Under Voltage Protection (UVP)

Over Current Protection (OCP)

Over Temperature Protection (OTP)

Foldback Protection

Interlock

Output Off

Shutdown activated (rear panel shutdown).

Internal hardware malfunction Fan failure

Hardware Malfunction Alarms

The power supply will turn off the output. An error message will be
displayed in the event that:

OVP trips

Voltage deviation in CV mode reaches more than ±5% from the set
level.

1

Current deviation in CC mode reaches more than ±5% from the set
level.

1


__________________________

1. These two forms of hardware malfunction are only monitored in the
corresponding APG mode.