background image



Local

Operation

3-36

M370430-01 Rev E

4.

Turn to display

or

.

5.

Press to commit the selected setting.

Important:

This single front panel operation affects both power on and

output enable. However, when using SCPI, there is a separate command
for each.

The SCPI command to query or enable/disable the 0 Voltage
Output Preset at power-on is:

[:]SYSTem[<channel>]:PON:VOLTage {?|ON|OFF}

The SCPI command to query or enable/disable the 0 Voltage
Output Preset upon output enable is:

[:]SYSTem[<channel>] :PON:ENAble:VOLTage {? |ON|OFF}

Programming Current Output Preset

To Enable/Disable automatic reset to 0 Amps:

1.

Turn the rotary Adjust/Enter control to PRT and press.

2.

Turn again until

is displayed.

3.

Press to display

.

4.

Turn to display

or

.

5.

Press to commit the selected setting.

Important: This single front panel operation affects both power on and
output enable. However, when using SCPI, there is a separate command
for each.

The SCPI command to query or enable/disable the 0 Current
Output Preset at power-on is:

[:]SYSTem[<channel>]:PON:CURRent {?|ON|OFF}

The SCPI command to query or enable/disable the 0 Current
Output Preset upon output enable is:

[:]SYSTem[<channel>] :PON:ENAble:CURRent {? |ON|OFF}