Applevel2 - c.8.5 no such object fakeq, Applevel1 - c.9 act error messages – Digi MIL-3000FTX User Manual

Page 127

Advertising
background image

MIL-3000FTX Series of FastPort Print Servers

C-11

C.8.3 Could not Read Configuration file from SERVER1

FastPort could not find the configuration file or did not have the rights to
read it.

• Configuration file is in the wrong location or misnamed

• An incorrect access right was given. Check its access rights:

a. Log in as

guest

.

b. Go to the

/login/milan

directory.

c. Type

rights

and press [Enter]. The system responds with the

current rights. Use the

Filer

command to change the rights if

necessary.

C.8.4 Trying to read file SYS:login/milan/FPXXXXXX on SERVER1

FastPort is looking for the configuration file on file server SERVER1.

C.8.5 No such object FAKEQ

There is no queue named FAKEQ. Verify it and the spelling of its queue
name.

C.8.6 Failed to login to file server SERVER1 for server FAKEPS

FastPort could not log into a nonexistent file server. The print server has
not been created in

PCONSOLE

. This error may also occur if the user has

modified the printer configuration in

PCONSOLE

. Remove any recent

configuration changes made.

C.9 ACT Error Messages

Print server not responding

• Power cycle the unit. Wait a minute and try again.

Error setting NVRAM value

• Usually due to a stale connection. Exit out of ACT and restart the utility.