Operation – Beisler 1282-4 User Manual

Page 21

Advertising
background image

Closing Seam Machine 1282-4 Working Instructions

- 12 -

Beisler Automated Sewing Equipment

Fig. 11

Fig. 11

4. Turn machine on by moving main switch to position I.

The display shows that the program control has not
been activated.

5. Power up program control by pressing program stop

switch. During this time, the display shows "RESET".

6. Unlock program stop switch (see Section B.2.4).

The machine is ready for operation.

B.3

Operation

B.3.2 Preparing the machine

Prior to the production start, check the supply connections,
connect the machine to the compressed air and power
supply systems and prepare the sewing head.

1. Insert needle, pass top and bottom thread through

needle (see working instructions of sewing head ma-
nufacturer or supplier).

2. Fig. 9: Connect machine to compressed air supply by

inserting the plug-in connector

2

of the compressed

air supply hose into the compressed air receptacle in
the operating room. The pressure of the compressed
air is reduced to the required operating pressure of 6
bar by a pressure reducer

1

. Check manometer

3

to see if the correct operating pressure is set. The
pressure reducer is installed at the side mounting wall
of the worktable.

3. Connect machine to power supply system.

WARNING - Electric shock!

Contact with current-carrying components may cause
a lethal electric shock. Check plug and cable before
connecting machine to power supply system.

Do not use damaged plugs, sockets or cables to
connect the machine to the power supply system!

The machine is connected to a power source of 230
V ±10 % at 50/60 Hz or 115 V ±10 % at 60 Hz (see Sec-
tion C, Specifications).

Before connecting the machine to the power supply
system, check to see if the ratings of the power sup-
ply system in the operating room correspond with the
ratings on the nameplate at the rear of the machine.

If the ratings for voltage (V) and maximum current (A)
do not match, the machine must not be connected.

Insert the grounding plug into a properly grounded and
fused power socket.

Make sure that the power supply cable is not subject
to tensile or pressure forces.

.

Advertising