Closing Seam Machine 1282-4 Working Instructions

- 12 -

Beisler Automated Sewing Equipment

C.5

Maintenance

Contour guide toothed belt replacement:

The two toothed belts for the contour guide stepper motors

(X rail and Y rail) are connected by a belt clamp.
1. Disconnect machine from power supply system.
2. Shift contour guide on X/Y rail manually until the cor-

responding rail clamp is accessible.

3. Fig. 7: Remove retaining screws

1

of belt cover

2

at the corresponding pedestal

3

and remove cover.

4 Remove fixing screws

4

of pedestal

3

to release

belt tension.

7. The belt clamp

6

is attached with four screws

5

tatthe X rail and with three screws

5

at the Y rail to

the stepper motor mounting plate. Remove screws and
remove toothed belt

7

.

8. Position new belt onto both pulleys.
9. Align belt

7

with holes at the ends to fixing pins and

secure belt clamp

6

to stepper motor mounting plate

using the screws.

10.Tension belt

7

by shifting pedestal and tightening fi-

xing screws

4

. In case of correct tensioning, it must

be possible to depress the center of the belt approx 10
mm until counterpressure is felt. Tighten fixing
screw

4

.

11. Install pedestal cover.

Fig. 7

Fig. 7