C.5

Maintenance

C.5.5 Machine set-up

Adjusting the seam control photocell:
Fig. 17:
The seam control photocell

1

controls the start

and the end of the sewing process. The red light beam

5

of the photocell should be positioned centrally on the re-
flective film

4

at distance A of approx 1.0-1.5 mm in front

of the needle

6

.

1. To position the light spot centrally on the reflective film,

loosen mounting bar fixing screw

3

and move bar into

desired position. Tighten fixing screw.

2. To position the light spot at the correct distance to the

needle, loosen photocell mounting fixing screw

2

and

shift mounting on mounting bar, then tighten fixing
screw.