Closing Seam Machine 1282-4 Working Instructions

- 4 -

Beisler Automated Sewing Equipment

C.2

Storage and location requirements

C.2.1 Floor quality

The floor of the room where the machine is to be instal-
led must have a sufficient surface strength. The location
of the machine must be free of vibrations.
If several machines are to be installed in one room, the
static load bearing capacity of the ceiling must be
considered.

Weight:

Machine with accessories

approx. 200 kg

C.2.2 Interior climate

Climatic requirements for the operating room:
The machine must only be stored or operated in closed
operating rooms.

Room temperature

+10 °C to +45 °C

Relative humidity

80 % max.

C.2.3 Floor space required

For operation during production and for service works, the
machine must be freely accessible from all sides. On all
sides, there must be a minimum clearance of 1 m.

Machine dimensions:

L x W x H

2700 x 1200 x 1900 mm

NOTE - Electromagnetic interference!

The machine must not be installed in the immediate vicinity
of devices or electrical components (e.g. transformers)
generating a strong magnetic field as otherwise the cor-
rect function of the program control may be impaired.

C.2.4 Supply connections

The machine requires on-site power and compressed air
sources.

Power connection:
The power supply of the machine requires a properly
grounded power connection with:

Grounding plug

230 V ± 10 %, 50/60 Hz

or

Safety plug

115 V ± 10 %, 60 Hz

Fusing

16 A

NOTE - Peak voltages!

The correct function of the machine requires that the power
system supplies a constant current. Peak voltages may
particularly impair the stability of the program control.

Compressed air supply:
The on-site compressed air supply system must meet the
following requirements:

Operating pressure

6 bar

Compressed air quality

oil-free

Compressed air consumption

4.16 NL/AT