Closing Seam Machine 1282-4 Working Instructions

Beisler Automated Sewing Equipment

C.5

Maintenance

C.5.4 Repairs

Any repairs to the machine must only be carried out by:

authorized Technical Service,

personnel that has been instructed about the setting
up and maintenance of the machine on the occasion
of a training by the supplier or manufacturer of the
machine.

Use only original spare parts for installing or replacing
machine components.
Manufacturer and supplier will not be held responsible for
spare parts from third parties.

NOTE - Programming instructions!

Repairs require that machine components carry out their
individual movements and that the machine movements
are tested. These functions are controlled on level 1 of the
service menu.
For the necessary instructions, please refer to the pro-
gramming instructions.

Operating panel replacement:
1. Disconnect machine from power supply.
2. Fig. 6: Remove two lock screws

2

and disconnect

interface connector

3

.

3. Remove retaining screws

1

from operating panel

bracket.

4. Remove operating panel

5

, install new panel and

secure using screws.

5. Connect interface connector to receptacle

4

and se-

cure using two lock screws

2

.

Fig. 6

Fig. 6