4 summary of specifications, 1 physical & environmental, 2 prime power – Comtech EF Data MBT-5003 User Manual

Page 22: 3 monitor & control, 4 reference

Advertising
background image

MBT-5003 L-Band Up/Down Converter System

Revision 1

Introduction

MN-MBT5003

1–6

1.4

Summary of Specifications

1.4.1

Physical & Environmental

Weight

20 lbs. (9.07 kg) Nominal

Dimensions (excluding connectors)

19” x 5.25” x 14” (482.6 x 133.35 x 355.6 mm) (See Figure 1-3)

Temperature

Operating

32º to 132.8ºF (0º to 56ºC)

Non-operating (Storage)

-58º to 158ºF (-50º to 70ºC)

Operational Altitude

15,000 ft above sea level

Shock

Normal commercial shipping and handling

1.4.2

Prime Power

AC Input

IEC-320 w/retainer

Voltage

AC

90 – 260 VAC

DC (optional)

48 VDC

Frequency

47 – 63 Hz

Dissipation

Up converter

100 Watts, typical

Down converter

80 Watts, typical

1.4.3

Monitor & Control

Serial M&C Interface

TIA/EIA-485, 4-wire DB-9F

Alarm

Form C, DB-9F

Remote Interface

RJ-45 Ethernet

Physical Controls

6-button keypad entry

Display

Vacuum Fluorescent Display (VFD), 24x2 alphanumeric

Status Indicators

5 LEDs per unit: SUM FLT, MUTE, ONLINE, UP, DOWN

1.4.4

Reference

External Input

5 or 10 MHz 5

±5 dBm, BNC Female

Output

5 MHz 10

±5 dBm Front Panel, BNC Female

Internal 10 MHz

Stability over Time

±1 x 10

-9

/day (higher stability optional)

Stability over Temp

±1 x 10

-8

Setability
(by remote control)

Resolution

Better than 2.5 x 10

-8

Range

>

±5 x 10

-7

Advertising