1 config: remote (remote control) – Comtech EF Data MBT-5003 User Manual

Page 47

Advertising
background image

MBT-5003 L-Band Up/Down Converter System

Revision 1

Front Panel Operation

MN-MBT5003

5–7

5.3.1.1

CONFIG: Remote (Remote Control)

Remote Control: Local
Serial Ethernet (◄ ► E)

Select Local, Serial, or Ethernet using the

◄ ►

arrow keys, then press ENT.

CONFIG: Remote Control

Æ Local

If Remote Control: Local is selected, then remote control will be disabled. Remote monitoring is
still possible.

CONFIG: Remote Control

Æ Serial

If Remote Control: Serial is selected:

Serial Config: Interface
Address Baudrate

Select Interface, Address, or Baudrate using the

◄ ►

arrow keys, then press ENT.

If Serial Config: Interface is selected:

M&C Bus Interface:
RS485-2W RS485-4W

Select RS485-2W (2-wire) or RS-485 (4-wire) using the

◄ ►

arrow keys, then press ENT.

If Serial Config: Address is selected:

Remote Address: 0001
(◄ ► ▲ ▼ E)

The valid range of addresses is from 1 to 9997. Use the ◄ ► arrow keys to select the
character to edit, then the ▲ ▼ arrow keys to edit the value of the digit, then press ENT.

If Serial Config: Baudrate is selected:

Local M&C Bus Baud Rate:
19200 Baud (▲ ▼ E)

Edit the baud rate of the remote control bus, connected locally to the M&C computer. The
value is changed using the

▲ ▼

arrow keys. Values of 2400, 4800, 9600,19200, and 38400

baud are available. Press ENT when done.

Note: The asynchronous character format is FIXED at 8 data bits, 1 stop bit, no parity (8-N-1).

CONFIG: Remote Control

Æ Ethernet

If Remote Control: Ethernet is selected:

Ethernet Config: Gateway
Address MAC SNMP (◄ ► E)

Select Gateway, Address, MAC, or SNMP using the

◄ ►

arrow keys, then press ENT.

Advertising