A–9

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are ASCII numeric codes

between 48 and 57)

Response to

Command

(Target to

controller)

Query

(Instruction

Code and

qualifier)

Response to query

(Target to controller)

Enable
Statistics
Averaging

ESA= 1

byte Command or Query.

Enables or Disables averaging of statistics data at a rate of once
per second for 10 second. If Disabled, burst values will be logged
instead of averaged values.
0 = Disabled
1 = Enabled

Default Value: 0

Example: <1/ESA=0’cr’
>0001/ESA=’cr’’lf’

ESA=
ESA?

ESA? ESA=x


(Same format as command
arguments)

Enable
Statistics
Logging

ESL= 1

byte Command or Query.

Enables or Disables the statistics logging function.
0 = Disable
1 = Enable

Default Value: 0

Example: <1/ESL=1’cr’
>0001/ESL=’cr’’lf’

ESL=
ESL?

ESL? ESL=x


(Same format as command
arguments)

Enable
Redundancy
Switch Mode

ESW= 1

byte Command or Query.

Turns ON or OFF the redundancy state, where:
0 = Off
1 = On

Default value: 1

Example: <1/ESW=1’cr’
>0001/ESW=’cr’’lf’

ESW=
ESW?
ESW *

ESW? ESW=x

Advertising