B.2 redundant operation, B.2.1 auto mode, B.2.2 force switchover – Comtech EF Data MBT-5003 User Manual

Page 96: B.2.3 gain equalization of redundant units, B.2.4 operational configuration commands

Advertising
background image

MBT-5003 L-Band Up/Down Converter System

Revision 1

Appendix B

MN-MBT5003

B–2

B.2

Redundant Operation

Refer to Appendix A. REMOTE CONTROL for further information about the remote commands
mentioned in this section.

B.2.1

Auto Mode

In this mode, one converter is always online (determined by the switch position and indicated on
the front panel), and the other converter is always offline and muted. If a fault is detected on the
online converter, either by loss of communications between the base unit and the online
converter, or via the summary fault, the base unit will switch the RF and IF switches and the
offline converter then become the active (online) unit (assuming the offline unit is not faulted).

B.2.2

Force Switchover

The online converter can be forced to become the offline unit (assuming the offline unit is not
faulted) either via the remote command (RED) or by front panel operation (

CONFIG

REDUN

FORCE

).

B.2.3

Gain Equalization of Redundant Units

Both converters are temperature compensated at same gain level, so the gain will stay the same
during a switchover.

B.2.4

Operational Configuration Commands

The attenuation command (ATT) sent to the online unit will be mirrored in the offline unit. The
commands sent to the offline unit will be rejected.