Comtech EF Data MBT-5003 User Manual

Page 91

Advertising
background image

MBT-5003 L-Band Up/Down Converter System

Revision 1

Appendix A

MN-MBT5003

A–15

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are ASCII numeric codes

between 48 and 57)

Response to

Command

(Target to

controller)

Query

(Instruction

Code and

qualifier)

Response to query

(Target to controller)

Retrieve Next
5
unread stored
Statistics

N/A variable

length

Query only.
Unit returns the oldest 5 Stored Statistics entries which have not
yet been read over the remote control. Reply format: {CR}Sub-
body{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-body,
where Sub-body=
ddmmyyhhmmssaaa.abbb.bccc.cddd.dee.eeff.ffghijkk.kll.l
ddmmyy = day/month/year
hhmmss = hour:minute:second
aaa.a = Conveter A Operating Temperature
bbb.b = Conveter B Operating Temperature
ccc.c = Converter A RF Power output
ddd.d = Converter B RF Power output
ee.ee = Converter A Attenuation Setting
ff.ff = Converter B Attenuation Setting
g = Converter A Mute On/Off
h = Converter B Mute On/Off
i = Converter A Online/Offline Status
j = Converter B Online/Offline Status
kk.k = Converter A Tuning Voltage
ll.l = Converter B Tuning Voltage

If there are less than 5 entries to be retrieved, the remaining
positions are padded with zeros.

If there are no new entries, the response is RNS*.

N/A RNS?

RNS={CR}Sub-
body{CR}Sub-
body{CR}Sub-
body{CR}Sub-
body{CR}Sub-body

(See Description of
Arguments)

Remote Baud
Rate

SBR= 4

bytes Command or Query.

Set remote baud rate as follows:
2400 = 2400 baud
4800 = 4800 baud
9600 = 9600 baud
19K2 = 19200 baud
38K4 = 38400 baud

Default Value: 9600

Example: <1/SBR=9600’cr’
>0001/SBR=9600’cr’’lf’

Note: When changing baud rates remotely the response to the
command will be returned using the same baud rate as that used
to send the command.

SBR=
SBR?

SBR?

SBR=xxxx

(Same format as command
arguments)

Advertising