2 config: fltrec (fault recovery) – Comtech EF Data MBT-5003 User Manual

Page 49

Advertising
background image

MBT-5003 L-Band Up/Down Converter System

Revision 1

Front Panel Operation

MN-MBT5003

5–9

If Trap is selected:

Trap Community: (◄ ►▲▼ E)
comtech

The user may view or edit the SNMP Trap Community string. To edit, first use the ◄
►arrows keys to select the character to edit, then the ▲ ▼ arrows keys to edit that
character. Press ENT when done.

If SNMP: Traps is selected:

SNMP Trap IP Address:
IP1 IP2 Version

Select IP1, IP2, or Version using the

◄ ►

arrow keys to, then press ENT.

If SNMP Trap IP Address: IP1 or IP2 is selected:

Trap IP #1:
000.000.000.000 (◄ ►▲▼ E)

Trap IP #2:
000.000.000.000 (◄ ►▲▼ E)

The user may edit the Trap Destination’s IP Addresses. To edit, first use the ◄ ►
arrow keys to select the digit to edit, then the ▲ ▼ arrow keys to edit the value of that
digit. Press ENT when done.

Note: If both Trap IP Addresses are 000.000.000.000, it means Traps are disabled.

If SNMP Trap IP Address: Version is selected:

Trap Version:
SNMPv1 SNMPv2 (◄ ► E)

Select the trap version – SNMPv1 or SNMPv2 – using the ▲ ▼ arrow keys, then
press ENT.

5.3.1.2

CONFIG: FltRec (Fault Recovery)

Fault Recovery: Manual
Automatic

Select Manual or Automatic using the

◄ ►

arrow keys, then press ENT.

5.3.1.3

CONFIG: ConvA or ConvB (Converter Unit ‘A’ or Converter Unit ‘B’)

Converter X
Mute/Freq Attenuation

Where ‘X’ is the selected converter – i.e., Converter (Unit) A or Converter (Unit) Bselect
Mute/Freq or Attenuation using the ◄ ► arrow keys, then press ENT.