Comtech EF Data MBT-5003 User Manual

Page 93

Advertising
background image

MBT-5003 L-Band Up/Down Converter System

Revision 1

Appendix A

MN-MBT5003

A–17

A.6.2 Block Converter (BUC/BDC) Remote Commands and Queries

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are ASCII numeric codes

between 48 and 57)

Response to

Command

(Target to

controller)

Query

(Instruction

Code and

qualifier)

Response to query

(Target to controller)

Attenuation ATT=

5

bytes,

Command or Query.
Valid attenuation level (00.00 to 50.00 for x-band BUC units, 00.00
to 20.00 for all other), in dB, in 0.25 dB steps as factory default.

Default Value: 00.00

Example: <2/ATT=12.25’cr’
>0002/ATT=’cr’’lf’

Note: Attenuation cannot be changed for the offline unit when in
redundancy mode.

ATT=
ATT?
ATT*

ATT? ATT=xx.xx


(Same format as command
arguments)

Operating RF
Frequency

FRE=xxxxx.x
xx

9 bytes

Command or Query.
Valid Operating RF frequency, in MHz.

For Ku BDCs only:
FRE values: 10950-11700 MHz an LO of 10000 MHz is activated
FRE values: 11700-12250 MHz an LO of 10750 MHz is activated
FRE values: 12250-12750 MHz an LO of 11300 MHz is activated

Example: FRE=11300.000‘cr’

Note: Operating Frequency cannot be changed for the offline unit
when in redundancy mode.

FRE=
FRE?
FRE*

FRE? FRE=x….x


(See Description of
Arguments)

Global
Converter
Configuration

GCC=

variable length

Command or Query.
Used to set up and query the global status of the BUC/BDC.

Example: GCC=aa.aa;b;ccccc.cc; ‘cr’ where:
aa.aa = attenuation in dB (ATT)
b = mute state, 0 = un-muted, 1 = muted (MUT)
ccccc.ccc = frequency in MHz (FRE, Ku BDC only, other units will
display xxxxx.xxx)

Note: This command can only be queried for the offline unit when
in redundancy mode.

GCC=
GCC?
GCC*

GCC? GCC=x….x


(See Description of
Arguments)

Mute State

MUT=

1 byte

Command or Query.
Mute the unit, where:
0 = Disabled (Not Muted)
1 = Enabled (Muted)

Default Value: 0

Example: <2/MUT=1’cr’
>0002/MUT=1’cr’’lf’

Note: Mute State cannot be changed for the offline unit when in
redundancy mode.

MUT=
MUT?
MUT*

MUT? MUT=x


(same format as command
arguments)

Advertising