MBT-5003 L-Band Up/Down Converter System

Revision 1

Appendix A

MN-MBT5003

A–3

A.4

Packet Structure

Controller-to-Target

Start of Packet

Target Address

Address Delimiter

Instruction Code

Code Qualifier

Optional

Arguments

End of Packet

<

ASCII code 60

(1 character)


(4 characters)

/

ASCII code 47

(1 character)

(3 characters)

= or ?

ASCII codes 61 or 63

(1 character)


(n characters)

Carriage Return

ASCII code 13

(1 character)

Example: <0412/MUT=1{CR}

Target-to-Controller

Start of Packet

Target Address

Address Delimiter

Instruction Code

Code Qualifier

Optional

Arguments

End of Packet

>

ASCII code 62


(1 character)

(4 characters)

/

ASCII code 47


(1 character)

(3 characters)

=, ?, !, or *

ASCII codes 61,63, 33

or 42

(1 character)

(From 0 to n

characters)

Carriage Return,

Line Feed

ASCII codes

13,10

(2 characters)

Example: >0412/MUT=1{CR}{LF}

A.4.1 Start of Packet

Controller-to-Target: This is the character '<' (ASCII code 60).

Target-to-Controller: This is the character '>' (ASCII code 62).

Because this is used to provide a reliable indication of the start of packet, these two characters may not appear anywhere else within the
body of the message.