Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are ASCII numeric codes

between 48 and 57)

Response to

Command

(Target to

controller)

Query

(Instruction

Code and

qualifier)

Response to query

(Target to controller)

Part Number

N/A

Various 1-96
bytes

Query only.
Returns the Comtech EF Data part number of the unit. This part
number is the unit’s DOTCODE at the time it was manufactured.
The DOTCODE may be up to 96 printable ASCII characters long.

Example: <2/PNM?’cr’
>0002/PNM=BUCC0.350WRSW00’cr’’lf’

N/A PNM?

PNM=x….x


(See Description of
Arguments for return string
details)

Redundancy
Online Status

RED=

1 byte

Command or Query.
When this command is used it will force the unit to throw the
switches causing the unit to go offline (if it is currently online). The
unit cannot be forced online, and sending a 1 will have no effect.
0 = Offline
1 = Online (query only)

Default value: 0

Example: <2/RED=0’cr’
>0002/RED=’cr’’lf’

RED=
RED?
RED*

RED? RED=x

Retrieve
Maintenance
Status

N/A

variable length

Query only.
Used to Query the Maintenance status of the unit.

N/A RMS?


RMS=x….x

(See Description of
Arguments)

Example

Description

<2/RMS?’cr’

>0002/RMS=’cr’
SYNVT=001.2’cr’
HSTMP=+12.3’cr’
FWPWR=004.9’cr’lf’




Synthesizer Voltage
Temperature
Forward Power

Note: If the converter does not support power monitor, will display
FWPWR=xxx.x

Serial Number

N/A

9 bytes

Query only.
Used to query the unit 9-digit serial number. Unit returns its S/N in
the form xxxxxxxxx.

Example: SNO=176500143

N/A SNO?

SNO=xxxxxxxxx

(See Description of
Arguments)

Temperature

N/A

4 bytes

Query Only.
Returns the temperatures of the heat sink in the form of a sign byte
followed by 3 bytes for the temperature.

Example: TMP=+26.0

N/A TMP?

TMP=sxxx

(See Description of
Arguments)