4 config: refadj (reference oscillator adjustment), 5 config: redun (redundancy) – Comtech EF Data MBT-5003 User Manual

Page 50

Advertising
background image

MBT-5003 L-Band Up/Down Converter System

Revision 1

Front Panel Operation

MN-MBT5003

5–10

If Mute/Freq is selected, and the unit is an MBT-5003-XUR Up Converter:

CONFIG CnvX:
Tx=On

Use the ▲ ▼ arrows keys to set Tx as ON or OFF (mute), then press ENT.
If Mute/Freq is selected, and the unit is an MBT-5003-XDR Down Converter:

CONFIG CnvX:
Rx=On

Use the ▲ ▼ arrows keys to set Rx as ON or OFF (mute), then press ENT.
Typical for both the MBT-5003-XUR and MBT-5003-XDR units, if Attenuation is selected:

CONFIG CnvX: Offst=+2.00
Attenuation = 00.00 dB

Note: Offst (Offset) will display only if the unit is an offline unit.

5.3.1.4

CONFIG: RefAdj (Reference Oscillator Adjustment)

Reference Frequency
Adjust: 087

Adjust the reference oscillator by using the ◄ ► arrow keys to select the digit to edit, then the ▲
▼ arrow keys to edit the value of that digit. Press ENT when done.
The default Reference Frequency tuning adjustment is 087, with allowable values from 0 to 255.

5.3.1.5

CONFIG: Redun (Redundancy)

Redundancy:
Disable/Enable Force

Note: While the user may select Disable/Enable or Force using the

◄ ►

arrow keys, the

Disable option is nonfunctional with the MBT-5003.

Redundancy Mode:
Disable Enable (◄ ► E)

Should the user attempt to select Disable using this menu, the following message displays:

Redundancy is always
Enabled for this unit.

The Disable/Enable menu will redisplay with the cursor set to Enable. Press ENT or CLR
to return to the previous menu.

If

Force is selected:

Press ENTER to Force
Converter A to Standby

As the display instructs, press ENT to force the redundant unit into standby mode.
Refer to Appendix B. MBT-5003 REDUNDANCY OPERATION for further information
on this feature.