Comtech EF Data MBT-5003 User Manual

Page 75

Advertising
background image

MBT-5003 L-Band Up/Down Converter System

Revision 1

Ethernet Management

MN-MBT5003

6–19

Clear Events Log: Select to clear all stored events from the log.
Initialize Events Pointer: Select to reset the internal pointer to allow queries to start at

the beginning of the stored events log.

Once a selection has been made, click [Submit] to execute the choice – the window will update
according to the selection made.

Alarm Mask

Note the following:

Low Noise Amplifier (LNA) operation is not supported by the MBT-5003. All alarm masks

associated with this feature are therefore nonfunctional.

• The Low Forward RF Power alarm masks are valid, when optionally configured, only for

the MBT-5003-XUR Up Converter.

Using the drop-down menus, select each alarm as Fault, Alarm or Masked for:

Low Forward RF Power (MBT-5003-XUR only)
Converter A Not Inserted
External Reference Lock Detected
Converter B Not Inserted

Once the desired configuration settings have been made in this section, click [Change Alarm
Mask]
to save these changes. Otherwise, click [Reset] if it is desired to revert back to the
previously assigned Alarm Mask settings, the user should instead click.