MBT-5003 L-Band Up/Down Converter System

Revision 1

Introduction

MN-MBT5003

1–7

1.4.5

BUC-5003 Block Up Converter (featured on MBT-5003-XUR)

Output Frequency

7900-8400 MHz

Input Frequency

1000-1500 MHz

Frequency Sense

No Inversion

Impedance

50

Ω

Input Return Loss

15 dB minimum

Output Return Loss

18 dB minimum

Input Connector

Type ‘TNC’ Female

Output Connector

Type ‘N’ Female

Gain

38

±2 dB nominal @ minimum attenuation

Full Band

±1.0 dB

Per 36 MHz

±0.50 dB

Per 20 MHz

±0.35 dB

0° to +56° C

.75 dB/15°C (

±1 dB, 0°-56 °C)

Mute

80dB

User Attenuation Range

0-50 dB, in 0.25 dB steps

Output Power, P1dB

22 dBm minimum

Noise Figure

15 dB @ minimum attenuation

Intermodulation Distortion

-30 dBc min w/2 output carriers @ 17 dBm each

AM/PM Conversion

0.1°/dB @ 0 dBm Output

Spurious (In-band)

Carrier Related

-75 dBc (<-80 dBc, typical)

Non-Carrier Related

-70 dBm

Related

Lo Leakage

-75 dBm

60 Hz & Harmonics

<-36 dBc (typically <-50 dBc)

Phase Non-linearity

Per 20 MHz BW

8 degrees p-p

Per 36 MHz BW

12 degrees p-p

Phase Noise

Meets or exceeds MIL-STD-188-164A

100 Hz

-68 dBc/Hz

1 kHz

-78 dBc/Hz

10 kHz

-88 dBc/Hz

100 kHz

-98 dBc/Hz

1 MHz

-108 dBc/Hz