2 select: monitor, 1 monitor: faults, 2 monitor: mask – Comtech EF Data MBT-5003 User Manual

Page 51

Advertising
background image

MBT-5003 L-Band Up/Down Converter System

Revision 1

Front Panel Operation

MN-MBT5003

5–11

5.3.2

SELECT: Monitor

Note: Low Noise Amplifier (LNA) operation is not supported by the MBT-5003. The LPT
selection on this submenu is therefore nonfunctional.

Monitor: Faults Mask
Event-Log LPT

Use the

◄ ►

arrow keys to select from the submenu choices shown, then press ENT. The following

table identifies each submenu available from the SELECT: Monitor menu branch – typical for
Converter Unit A or Unit B – its content section in this chapter, and functional description of each
submenu:

Submenu

Sect

Functional Description

Faults

5.3.2.1

Displays the active faults for the base unit and the converters.

Mask

5.3.2.2

Permits the user to configure Alarm Mask (MSK) conditions.

Event-Log

5.3.2.3

Display stored events. Also permits the user to clear the events.

5.3.2.1

MONITOR: Faults

Live Faults: Unit ConvA
ConvB (◄ ► E)

Select Unit, ConvA, or ConvB using the

◄ ►

arrow keys, then press ENT.

If Unit is selected, the highest level fault for the base unit will appear. If no Unit faults exist,
the message “

No Errors

” is displayed:

Unit Fault:
No Errors

Press ENT to return to the previous menu.

If ConvA or ConvB is selected, the highest fault for the converter will appear. If no converter
faults exist, the message “

No Errors

” is displayed:

ConvA Fault:
No Errors

Press ENT to return to the previous menu.

5.3.2.2

MONITOR: Mask

Note: The Power selection on this submenu is operable only when the MBT-5003-XUR is
optionally configured with the Power Monitor option. Low Noise Amplifier (LNA) operation is
not supported by the MBT-5003 – the LNA selection is therefore nonfunctional.

Alarm Mask: Power ExtRef
ConvA ConvB LNA (◄ ► E)