Parameter Modification

PL1877A Microprocessor Radio Telephone Interconnect

12/10 94

Dial Tone Detection

Parameter Function

64

Disable disconnection upon detection of dial tone for a land-line originated call = 0
Enable disconnection upon detection of dial tone for a land-line originated call = 1
Default = 0

General Call Characteristics

Parameter Function

13

Disable mobile call origination = 0
Enable mobile call origination = 1
Default = 1

14

Disable land-line call origination = 0
Enable land-line call origination = 1
Default = 1

15

Disable attendant call origination = 0
Enable attendant call origination = 1
Default = 1

Call Timers

Parameter Function

360

The length of time before disconnect that time out warning ticks are generated.
Valid range = 0–59 seconds.
If this parameter is programmed to 0, time-out ticks are disabled.
Default = 15

Overall Access Timer

Parameter Function

18

Don’t allow mobile user to override access time limit with *** command = 0
Allow mobile user to override access time limit with *** command = 1
Default = 0

19

*** command (entered during conversation) resets overall access timer to 1 minute = 0
*** command (entered during conversation) resets overall access timer to duration
specified by parameter 357 = 1
Default = 1

357

Overall access timer. Valid range = 1–59 minutes.
Any number greater than 59 sets the overall access time to an infinite duration.
Default = 1 minute