T1600 series remote interfacing – GAI-Tronics MRTI 2000 (No. PL1877A) Microprocessor Radio Telephone Interconnect Installation & Service Manual User Manual

Page 159

Advertising
background image

PL1877A Microprocessor Radio Telephone Interconnect

PL1877A – Radio Installation

153

12/10

T1600 Series Remote Interfacing

In this mode of operation, the PL1877A normally operates in the enhanced VOX simplex mode.
Receiver audio is used as the receiver carrier source. Connect the PL1877A radio cable to the remote as
follows:

Radio Cable Interfacing

Color Function

Terminal

Green/white

Receive audio high

13

Black/green

Receive audio low

12

Blue/white

Transmit audio high

28

Blue/black

Transmit audio low

27

White PTT

15

Green PTT

return

1

Orange

Monitor (rec PL disable)

19

Yellow Monitor

return

1

Blue

Receive carrier indicate

n. c.

Red/black

Transmit PL disable

n. c.

Red

Transmit PL disable return

n. c.

#12 black ground

Logic/lightning ground

1

It is recommended to use the optional ac transformer and cable on remote installations. Install the ac
power connector into the 5-pin DIN connector (DC PWR), on the rear panel of the PL1877A.

Required Parameter Settings – Using the “Parameter Modification Procedure” section of this manual
set the following parameters:

Parameter Setting

1 0

(de-emphasis)

2

1, JU202 IN (high level speaker audio)

3

0 (internal carrier detect)

4 Don’t

care

5

1 (RX audio VOX for carrier detect

6 Don’t

care

7 Don’t

care

9 1

(simplex)

10

0 (active low PTT sense input

70

1 (enhanced VOX, requires enhanced VOX option

Advertising