Parameter Modification

PL1877A Microprocessor Radio Telephone Interconnect

12/10 88

Telephone Interface

Parameter Function

163

Off-hook voltage threshold is 25 V = 0

Off-hook voltage threshold is 15 V = 1

Allow user to manually set off-hook voltage threshold via test 6 (or programming
software) = 2

Default = 0

This parameter is required for determining the off-hook voltage threshold on the
PL1877A’s phone line. This allows the PL1877A to determine when an attendant (line-
sharing) telephone is in use.

Program parameter 163 to 0 for a phone line that provides a 48 V talk battery.

Program parameter 163 to 1 for a phone line that provides a 24 V talk battery.

If the phone line provides substantially less than 24 V of talk battery, it may be necessary
to manually program the off-hook threshold via test 6 (or via the programming software).
If so, program parameter 163 to 2.

123

Number of rings that PL1877A must receive before generating ring signaling to mobile.

Valid range = 1–9.

Default = 1

This parameter is used to delay ring signaling to the mobile long enough for an attendant
to answer the call via a line sharing telephone.