GAI-Tronics MRTI 2000 (No. PL1877A) Microprocessor Radio Telephone Interconnect Installation & Service Manual User Manual

Page 116

Advertising
background image

Parameter Modification

PL1877A Microprocessor Radio Telephone Interconnect

12/10 110

Para-
meter
No.



Description



Control Digits

Refer to
Section on
Page:

139–144 Prefix to * attendant access code - the code

an attendant user enters as a prefix to the *
command before being granted direct
channel access or selective signaling
privileges.

Valid range = 0–$D

101

145–150 Landline remote parameter programming

code - when enabled, the code must be
entered as a prefix to one of the landline
programming commands.

Valid range = 0–9, A–D, FF
Default = disabled

90

163

Off-hook Voltage Threshold

See appropriate section.

88

165

Time between automatically answering a
land-line call and generating a beep
prompt (time = 500 ms + x)50 ms))

Valid range = 0–15
Default = 0

99

177–196 Auto-dial location #1.

See appropriate section.

98

197–216 Auto-dial location #2.

See appropriate section.

98

217–236 Auto-dial location #3.

See appropriate section.

98

237–256 Auto-dial location #4.

See appropriate section.

98

257–276 Auto-dial location #5.

See appropriate section.

98

277–296 Auto-dial location #6.

See appropriate section.

98

297–316 Auto-dial location #7.

See appropriate section.

98

317–336 Auto-dial location #8.

See appropriate section.

98

337–356 Auto-dial location #9.

See appropriate section.

98

357

Overall access time limit. Any number
greater than 59; sets the overall access
time limit to an infinite duration.

Valid range = 1-59 minutes
Default = 0

94

358

The number of 25-ms periods in the signal
search frequency.

Valid range = 10–100

83

359

The number of 5-ms periods in the signal
search sample duration.

Valid range = 3–20

83

360

The length of time before disconnect that
time out warning ticks are generated.

Valid range = 0–59 seconds
Default = 15

94

361

Determines the time between SID
transmissions. If this parameter is
programmed to 0, periodic SID is disabled.

Valid range = 0–59 minutes

95

362-367 Multi-digit access prefix #1.

Valid range = 0–9, A–D, FF

91

368-373 Multi-digit access prefix #2.

Valid range = 0–9, A–D, FF

91

374-379 Multi-digit access prefix #3.

Valid range = 0–9, A–D, FF

91

380-385 Multi-digit access prefix #4.

Valid range = 0–9, A–D, FF

91

Advertising