Features PL1877A

Microprocessor Radio Telephone Interconnect

12/10 122

Motorola/EIA 5-Tone

5-Tone capcodes consist of five digits. If dual addressing is enabled, a sixth digit is required.

Selective Signaling Parameters and Functions

Parameter Function

1001

Disable selective signaling from a land-line caller on line 1 = 0

Enable selective signaling from a land-line caller on line 1 = 1

1007

Disable selective signaling from a land-line caller on line 2 = 0

Enable selective signaling from a land-line caller on line 2 = 1

1002

Disable selective signaling from an attendant = 0

Enable selective signaling from an attendant = 1

Default = 0

1003

Disable mobile revertive signaling = 0

Enable mobile revertive signaling = 1

Default = 0

General Selective Signaling Characteristics

Selective Signaling Password

Refer to Direct Access/Selective Signaling Password in the Parameter Modification Procedure section on
page 101 of this manual.

Paging Tone Transmission Characteristics

Parameter Function

1004

Deactivate the PL strip output during transmission of selective signaling tones = 0

Enable the PL strip output during transmission of selective signaling tones = 1

1006

Disable 6 dB/octave de-emphasis of selective signaling tones = 0

Enable 6 dB/octave de-emphasis of selective signaling tones = 1

1087

Number of times to repeat signaling. Valid range = 0–8

If the mobile fails to respond to a page in the time specified by parameter 1008, the
PL1877A can repeat the paging sequence and wait again. This parameter determines the
maximum number of times this occurs before disconnection.

1088

Mobile answer time - time for a mobile to answer a selective call before disconnection
(in single mode) or advancing to a linked user ID (in multi-mode). This parameter is x in
the following equation: Time = 10 seconds (1 + x). Valid range = 0–15