Parameter modification via modem – GAI-Tronics MRTI 2000 (No. PL1877A) Microprocessor Radio Telephone Interconnect Installation & Service Manual User Manual

Page 84

Advertising
background image

Parameter Modification

PL1877A Microprocessor Radio Telephone Interconnect

12/10 78

Clear Parameters – Parameters may be cleared by entering the command sequence: C OP1 OP2 <cr>,
where OP1 is the starting parameter number and OP2 is the ending parameter number.

Display Parameters – Parameters may be displayed on the screen by entering the command sequence D
OP1 OP2 <cr>, where OP1 is the starting parameter number and OP2 is the ending parameter number.

View Parameters – Parameters may be displayed and opened for modification by entering the command
sequence No. <cr> where No. is the number of the parameter to be modified. After entering the No. <cr>
command, the parameter number chosen is displayed along with the current value of this parameter. To
change the value, enter the new value and then close the location by pressing

ENTER

. The next

parameter is then displayed.

1. Press the ^J (CTRL and J entered simultaneously) or the

DOWN

arrow to display the previous

parameter.

2. Press the ^K (CTRL and K entered simultaneously) or the

UP

arrow to display the next parameter.

3. Press the ^U (CTRL and U entered simultaneously) or the PgUp button to display parameters in

increments of 10.

4. Press the ^D (CTRL and D entered simultaneously) or the PgDn button to display parameters in

decrements of 10.

Help Screen – To regain the help screen at any time during the routine, enter a ? <cr> (question mark) at
the prompt.

Exit – To exit the parameter modification routine and cease communication between the patch and the
video display terminal, enter the sequence ^X (CTRL and X pressed simultaneously).

N

OTE

: Generally, when entering parameter values larger than 9, the hexadecimal equivalent of the

parameter value must be entered (as opposed to the decimal value). For example, to program the overall
access timer to a duration of 59 minutes, 3B (the hexadecimal equivalent of 59) must be entered.

Parameter Modification via Modem

The modem feature allows operating parameters to be programmed, checked or modified remotely using
a computer equipped with a modem. The format is Bell 212A operating at 1200 baud. Modification of
parameters requires the computer modem software to work in a terminal emulation program, such as
VT100/ANISE, or other program that supports ASCII characters. This feature can be enabled or disabled
via parameter 22.