Parameter Modification

PL1877A Microprocessor Radio Telephone Interconnect

12/10 112

Para-
meter
No.



Description



Control Digits

Refer to
Section on
Page:

496–499 Four-digit emergency access number

excepted from toll restrictions.

Valid range = 0–9 (4 digits)

97

500

Maximum phone number length allowed.
If this parameter is greater than 20, an
entry of 20 is assumed.

Valid range = 1–20

97

501–512 Station ID (SID)

See appropriate section.

95

514

Enhanced VOX delay.

Valid range = 0–100
Default = 100

84

515–517 Override table entry corresponding to

multi-digit access prefix #1.

See appropriate section.

91

518–520 Override table entry corresponding to

multi-digit access prefix #2.

See appropriate section.

91

521–523 Override table entry corresponding to

multi-digit access prefix #3.

See appropriate section.

91

524–526 Override table entry corresponding to

multi-digit access prefix #4.

See appropriate section.

91

527–529 Override table entry corresponding to

security code.

See appropriate section.

91

530–535 Wildcard access/release code template - a

6-byte template that defines the structure
of wildcard access/release codes. The
code appearing in the template must be
right justified (the last digit of the template
must be in parameter 535). Filling the
template with $FF disables wildcard
features.

Refer to the Wildcard
Access/Release section in this
manual.

91

549

Signaling pretime - the delay between
activating the PTT and generating mobile
signaling.

Valid range = 0–24
Default = 3

87

1001

Determines whether selective signaling
from a landline caller on line 1 is enabled
or disabled.

0 = Disabled
1 = Enable
Default = 0

117

1002

Determines whether selective signaling
from an attendant is enabled or disabled.

0 = Disabled
1 = Enable
Default = 0

119

1003

Determines whether mobile revertive
mobile-to-mobile signaling is enabled or
disabled.

0 = Disabled
1 = Enable
Default = 0

119

1004

Determines whether the PL strip output
during transmission of selective signaling
tones is activated or deactivated.

0 = Deactivate
1 = Activate

122

Advertising