GAI-Tronics MRTI 2000 (No. PL1877A) Microprocessor Radio Telephone Interconnect Installation & Service Manual User Manual

Page 113

Advertising
background image

PL1877A Microprocessor Radio Telephone Interconnect Parameter

Modification

107

12/10

Para-
meter
No.



Description



Control Digits

Refer to
Section on
Page:

46

Allows 9 as the first telephone digit.

0 = Don’t allow
1 = Allow

97

47

Allows 1 as the first telephone digit.

0 = Don’t allow
1 = Allow

97

48

Allows 0 as the first telephone digit.

0 = Don’t allow
1 = Allow

97

49

Determines whether toll restriction applies
to auto-dial numbers.

0 = Does not apply
1 = Applies
Default = 0

98

50

Determines whether * access command is
required from a landline user on line 1
before allowing direct channel access or
selective signaling input.

0 = Don’t require
1 = Require
Default = 1

101

51

Determines whether * access command is
required from attendant user before
allowing a direct channel access or
selective signaling input.

0 = Don’t require
1 = Require
Default = 1

101

52

Enable or disable SID on patch release.

0 = Disable
1 = Enable

95

53

Determines whether the mobile user is
restricted to using the auto-dial feature for
dialing telephone numbers.

0 = Don’t restrict
1 = Restrict
Default = 0

98

54

Allows a mobile user to access a busy
phone line with the *** command.

0 = Don’t allow
1 = Allow
Default = 0

103

55 Enables/disables

mobile modification of

auto-dial numbers.

0 = Disable
1 = Enable
Default = 1

90

56

Determines whether the station/repeater
enable feature is enabled or disabled.

0 = Disable
1 = Enable
Default = 0

103

57

Enables or disables a mobile users ability
to modify parameters with a DTMF
keypad.

0 = Disable
1 = Enable
Default = 0

90

58

Enable or disables landline direct channel
access.

0 = Disable
1 = Enable
Default = 0

99

59

Enable or disables attendant direct channel
access.

0 = Disable
1 = Enable
Default = 0

99

Advertising