PL1877A Microprocessor Radio Telephone Interconnect Parameter

Modification

95

12/10

Mobile Inactivity Timer

Parameter Function

122

Mobile inactivity timer. This parameter determines how long the PL1877A keeps the
phone line accessed without detection of mobile carrier.
Valid range = 0-14. This parameter is x in the following equation: mobile inactivity
timer = 30 seconds + x (30 seconds).
If set to 15 (hexadecimal F), the mobile inactivity timer is disabled.
Default = 0

Semi-private Operation

PL Strip Control

Parameter Function

32

Automatically activate PL strip relay on access = 1
Do not activate PL strip relay on access = 0
Default = 0

Selectable Features

Station Identification (SID or CWID)

Parameter Function

52

Disable SID on patch release = 0
Enable SID on patch release = 1

62

Do not transmit the SID if it is time to do so and no station PTT has occurred since the
last SID transmission = 0
Transmit the SID if it is time to do so and no station PTT has occurred since the last SID
transmission = 1

361

The time, in minutes, between SID transmissions. Valid range = 0–59 minutes.
If this parameter is programmed to 0, periodic SID is disabled.

501-512

Station ID (SID) - enter the SID in ASCII as shown in the table below.
N

OTE

: ASCII equivalents are given in hexadecimal.