Micor rcb repeater – GAI-Tronics MRTI 2000 (No. PL1877A) Microprocessor Radio Telephone Interconnect Installation & Service Manual User Manual

Page 155

Advertising
background image

PL1877A Microprocessor Radio Telephone Interconnect

PL1877A – Radio Installation

149

12/10

MICOR RCB Repeater

PL1877A Half-duplex mode: To facilitate easier installation and servicing, the screw terminals (TB3)
should be used for connection of the PL1877A P1 interface cable. The following jumper wires should be
soldered into the holes adjacent to the screw terminals rather than wrapping the jumper ends around the
terminals. Install the following jumpers:

From To

Function

1. Screw terminal #9

J5 pin 9

PL stripping

2. Screw terminal #13

Sta cont Pin 21

R1 disc

3. Screw terminal #15

F1-PL pin 22

Exciter input

4. Screw terminal #17

J2-10

PL indicator

In order to use the PL stripping function, a jumper must also be installed from P701 on the PL encoder
board to P964 on the transmitter interconnect board. This jumper is also used with the paging PL defeat
option.

Installation of P1 Interface Cable

Cable Color

To

Function

Red

Screw terminal #1

PL stripping return

Orange/black

Screw terminal #1

PTT return

Green/black

Screw terminal #1

RX audio return

Blue/black

Screw terminal #1

TX audio return

Red/black Screw

terminal #9

PL stripping

Green/white

Screw terminal #13

RX disc audio

White

Screw terminal #14

Repeater PTT

Blue/white

Screw terminal #15

TX audio

Black Screw

terminal #17

PL indicator

If the PL1877A is to be dc-powered, connect the red lead in the dc power cable to screw terminal #10
and the black lead to screw terminal #1; connect the other end of the dc power cable into the 5-pin DIN
connector (DC PWR), on the rear panel of the PL1877A. If the optional ac transformer and cable are to
be used, install the ac power connector into the 5-pin DIN connector (DC PWR), on the rear panel of the
PL1877A.

Earth ground - run the supplied #12 (or larger) wire from the GND terminal on the PL1877A to the base
station chassis ground. This wire must be as short as practical, not coiled, and fastened securely to the
base station chassis.