Miscellaneous – GAI-Tronics MRTI 2000 (No. PL1877A) Microprocessor Radio Telephone Interconnect Installation & Service Manual User Manual
Page 93

PL1877A Microprocessor Radio Telephone Interconnect Parameter
Modification
87
12/10
Miscellaneous
Receiver Input Audio Source
The input from the receiver is obtained from either a pre-emphasized source requiring de-emphasis
(discriminators and detectors) or from a de-emphasized (flat) source (volume control or speaker).
Parameter 01 is set to match the source.
Parameter Function
1
RX audio source is pre-emphasized = 0
RX audio source is flat = 1
Receiver Input Audio Level
The input from the receiver is obtained from either a high, mid, or low level source. Parameter 2 and
jumper JU202 must be set to match the receiver audio source. Refer to the following information in
determining the required state of parameter 2 and jumper JU202.
Audio Source Level
Parameter 2
JU202
2.5 V ac
1
In
0.5 V ac
1
Out (default)
80 mV ac
0
Out
Parameter Function
10
PTT sense input is active low = 0
PTT sense input is active high = 1
Default = 0
65
Patch inhibit input is active low = 0
Patch inhibit input is active high = 1
Default = 0
549
Signaling pretime – This parameter sets the delay between activating the PTT and
generating mobile signaling (rings, paging beeps, SID, etc.). This number is x in the
following equation: pretime = 100 ms (x + 1).
Valid range = 0–24.
Default = 3