Parameter Modification

PL1877A Microprocessor Radio Telephone Interconnect

12/10 100

Parameter Function

58

Disable land-line direct channel access on line 1 = 0
Enable land-line direct channel access on line 1 = 1
Default = 0

42

Disable land-line direct channel access on line 2 = 0
Enable land-line direct channel access on line 2 = 1
Default = 0

59

Disable attendant direct channel access = 0
Enable attendant direct channel access = 1
Default = 0

61

Deactivate PL strip output during direct access time = 0
Activate PL strip output during direct access time = 1
Default = 0

165

The time between automatically answering a land-line call and generating a beep prompt
(time = 500 ms + x (50 ms)). Valid range = 0–15
Default = 0

Direct Access Timer

Parameter Function

25

Disable revert from direct access timer to overall access timer upon detection of mobile
carrier during direct access time = 0
Enable revert from direct access timer to overall access timer upon detection of mobile
carrier during direct access time = 1
Default = 0
N

OTE

: If wildcard access is required to perform this function in conjunction with the

selective signaling option, this parameter is ignored. Refer to Wildcard Access/Release
section.

126

Direct access duration: number of 5 second periods in direct access time. This parameter
is x in the following equation: direct access duration = 5 seconds (1 + x).
Valid range = 0–8
Default = 0