Parameter Modification

PL1877A Microprocessor Radio Telephone Interconnect

12/10 114

Para-
meter
No.



Description



Control Digits

Refer to
Section on
Page:

1084

Determines the number of digits accepted
from an attendant for selective signaling.
The valid range depends on the type of
selective signaling selected.

0–6 = DTMF, 2805, 1500
0–3 = 2-Tone
0–4 = Plectron
0–6 = Motorola/EIA

123

1085

Determines the number of digits accepted
from a mobile user for selective signaling.
The valid range depends on the type
selective signaling selected.

0–6 = DTMF, 2805, 1500
0–3 = 2-Tone
0–4 = Plectron
0–6 = Motorola/EIA

123

1087

Determines the number of times to repeat
signaling.

Valid range = 0–8

122

1088

Mobile answer time - the number of 10-
second increments for a mobile to answer
a selective call before disconnection or
advancing to an alternate user ID.

Valid range = 0–15

122

1089

Landline and attendant DTMF dialing
inter-digit time - the time between digits
being entered as selective signaling input.

Valid range = 0–15

123

1090

DTMF outpulse timing - the number of 50-
ms periods in the DTMF digit/inter-digit
time.

Valid range = 0–8

126

1091

2-Tone paging A tone length - the number
of .5-second increments in the duration of
the first tone of a 2-Tone sequence.

Valid range = 0–8

126

1092

2-Tone paging B tone length - the number
of .5-second increments in the duration of
the second tone of a 2-Tone sequence.

Valid range = 0–8

126

1093

Plectron paging A tone length - the number
of .5-second increments in the duration of
the first tone of a Plectron tone sequence.

Valid range = 0–8
(.5 to 4.5 seconds)

121

1094

Plectron paging B tone length - the number
of .5 second increments in the duration of
the second tone of a Plectron tone
sequence.

Valid range = 0–8
(.5 to 4.5 seconds)

121

1095

2805 Tone off time - the number of 10-ms
periods in tone off time for 2805 paging.
This parameter is x in the following
equation: 10 ms + x (10 ms).

Valid range = 0–8
(10–90 ms)

127

1096

1500 Tone off time - the number of 10 ms
periods in tone off time for 1500 paging.

Valid range = 0–8
(10–90 ms)

127