Verilink AS4000 (34-00244) Product Manual User Manual

Page 19

Advertising
background image

Overview

Verilink AS4000 User Manual

1-9

Table 1-4

AS4000 Power Supplies

AS4011

AS4004

DC Inputs:

-48VDC Power Input (range 38 to 60 VDC), 250W max.
(Approvals based on 48+/-10%; 43.2-52.8VDC Talk Bat-
tery (5A max.)
-48VDC Signalling Battery (5A max.)
Maximum heat dissipation in unit from Talk and Signal-
ling Battery is 120W. Maximum total heat dissipation in
unit is therefore 370W.

AC Input:

110VAC 47 to 63 Hz (Range 90 to 132VAC), 250W max.
(Approvals based on 100 to 240, +6%-10% 200W),
220VAC 47 to 63 Hz (Range 180 to 264VAC), 250W
max.

DC Inputs:

-24VDC (range 21.6 to 36VDC), 100W 26.4VDC.
(Approvals based on 24+/-10%; 21.6 to 26.4VDC
-48VDC power input (range 43-56VDC), 100W
(Approvals based on 48+/-10%; 43.2 to 52.8VDC)
-48VDC Talk Battery (1.5A max.)
-48VDC Signalling Battery (1.5A max.)
Maximum heat dissipation in unit from Talk and Signal-
ling Battery is 48W. Total heat dissipation in DC unit is
therefore 148W maximum.

AC Input:

110VAC or 220VAC, 47 to 63Hz (range 90 to 264VAC),
125W (Approvals will be based on rating 100 to
240VAC, +6%/-10%)

Advertising