Ds-1 port configuration, Ds-1 port configuration -2 – Verilink AS4000 (34-00244) Product Manual User Manual

Page 90

Advertising
background image

Quad DS-1 Module

5-2

Verilink AS4000 User Manual

DS-1 Port

Configuration

The Quad DS-1 configuration files are stored on the System
Controller. Thus, when replacing a Quad DS-1 module, the old
configuration will be preserved.

Figure 5-2 Quad DS-1 Port Configuration Menu

Table 5-1

Quad DS-1 Port Configuration Menu.

Ver

Ver

Ver

Veri

i

i

ilink

link

link

link C

C

C

Corpor

orpor

orpor

orpora

a

a

ation

tion

tion

tion

AS

AS

AS

AS4

4

4

4000 - Quad T1

000 - Quad T1

000 - Quad T1

000 - Quad T1

Slot:

Slot:

Slot:

Slot:0

0

0

05

5

5

5 H

H

H

Help =

elp =

elp =

elp =

[?]

[?]

[?]

[?]

Qua

Qua

Qua

Quad

d

d

d T-1

T-1

T-1

T-1 c

c

c

card po

ard po

ard po

ard por

r

r

rt con

t con

t con

t conf

f

f

figura

igura

igura

igurat

t

t

tion

ion

ion

ion

P

P

P

Po

o

o

ort #1

rt #1

rt #1

rt #1

Port

Port

Port

Port #2

#2

#2

#2 Po

Po

Po

Por

r

r

rt #3

t #3

t #3

t #3 Port

Port

Port

Port #

#

#

#4

4

4

4

Nam

Nam

Nam

Name

e

e

e.....

.....

.....

......

.

.

...: P

..: P

..: P

..: Po

o

o

ort #1

rt #1

rt #1

rt #1

Port

Port

Port

Port #2

#2

#2

#2 Po

Po

Po

Por

r

r

rt #3

t #3

t #3

t #3 Port

Port

Port

Port #

#

#

#4

4

4

4

Fra

Fra

Fra

Fram

m

m

ming..

ing..

ing..

ing...

.

.

...: E

..: E

..: E

..: ES

S

S

SF

F

F

F

ESF

ESF

ESF

ESF

ES

ES

ES

ESF

F

F

F

ESF

ESF

ESF

ESF

Lin

Lin

Lin

Line

e

e

e code

code

code

code.

.

.

...: B

..: B

..: B

..: B8

8

8

8ZS

ZS

ZS

ZS

B8ZS

B8ZS

B8ZS

B8ZS

B8

B8

B8

B8Z

Z

Z

ZS

S

S

S

B8ZS

B8ZS

B8ZS

B8ZS

LBO

LBO

LBO

LBO.

.

.

......

.....

.....

......

.

.

...: 0

..: 0

..: 0

..: 0

db

db

db

db

0 db

0 db

0 db

0 db

0

0

0

0 d

d

d

db

b

b

b

0 db

0 db

0 db

0 db

Den

Den

Den

Dens

s

s

sity..

ity..

ity..

ity...

.

.

...: C

..: C

..: C

..: Cl

l

l

lear

ear

ear

ear

Clea

Clea

Clea

Clear

r

r

r

Cl

Cl

Cl

Cle

e

e

ear

ar

ar

ar

Clear

Clear

Clear

Clear

Ntw

Ntw

Ntw

Ntwk

k

k

k loop

loop

loop

loops

s

s

s..: E

..: E

..: E

..: En

n

n

nable

able

able

able

Enable

Enable

Enable

Enable En

En

En

Ena

a

a

able

ble

ble

ble Enabl

Enabl

Enabl

Enable

e

e

e

Yel

Yel

Yel

Yell

l

l

low al

ow al

ow al

ow ala

a

a

arm: Y

rm: Y

rm: Y

rm: Ye

e

e

es

s

s

s

Yes

Yes

Yes

Yes

Ye

Ye

Ye

Yes

s

s

s

Yes

Yes

Yes

Yes

ESF

ESF

ESF

ESF format..: 54

format..: 54

format..: 54

format..: 54016

016

016

016

54016

54016

54016

54016

54

54

54

540

0

0

016

16

16

16

54016

54016

54016

54016

Unu

Unu

Unu

Unus

s

s

sed DS

ed DS

ed DS

ed DSO

O

O

O's: B

's: B

's: B

's: Bu

u

u

usy

sy

sy

sy

Busy

Busy

Busy

Busy

Bu

Bu

Bu

Bus

s

s

sy

y

y

y

Busy

Busy

Busy

Busy

Por

Por

Por

Port

t

t

t Stat

Stat

Stat

Statu

u

u

us : I

s : I

s : I

s : In

n

n

n Serv

Serv

Serv

Servi

i

i

ice

ce

ce

ce

In S

In S

In S

In Se

e

e

ervice

rvice

rvice

rvice

In

In

In

In Service In Se

Service In Se

Service In Se

Service In Ser

r

r

rvice

vice

vice

vice

Cas

Cas

Cas

Casc

c

c

cade L

ade L

ade L

ade Le

e

e

eds wh

ds wh

ds wh

ds whe

e

e

en Idl

n Idl

n Idl

n Idle

e

e

e: Yes

: Yes

: Yes

: Yes

Name

This is a user-defined field. Any name up to 14 characters in length can be entered to

identify each port on the Quad DS-1. Some users find it beneficial to use circuit

numbers to name the ports.

Framing

This information must be obtained from the network supplier. Choose either D4 or

ESF.

D4 (SuperFrame) consists of 12 frames of 193 bits each for a total of 2316 bits. Each

193 bit frame consists of 192 bits preceded by one framing bit (the F bit).

ESF (Extended SuperFrame) includes provisions for continuous monitoring by both the

user and the telephone company central office. ESF provides a 4 Kbit/s link control

channel (transparent to user data) which allows the telephone company to monitor the

local loop, transmit and receive test messages and retrieve performance data—all

without interrupting normal operations.

Line Code

This information must be obtained from the network supplier. Choose between AMI

(Alternate Mark Inversion) and B8ZS (Bipolar with 8 Zero Substitution).

LBO (Line Build

Out)

Set to 0 dB unless the network supplier specifically requests otherwise. The options

are 0, 7.5, 15 or 22 dB.

Density

This information must be obtained from the network supplier. Choose Clear or 62411.

A Clear network imposes no ones density requirements on the user. A 62411 network

complies with AT&T Technical Reference #62411 and limits the AS4000 Quad DS-1

module transmission to no more than fifteen consecutive zeros. If the Line Code entry

is B8ZS, choose Clear. If the Line Code entry is AMI, choose 62411.

Advertising