H3C Technologies H3C Intelligent Management Center User Manual

Page 86

Advertising
background image

77

c.

Select the target storage device. This field supports the suggestion function. For example, if

you enter 5, all storage devices that contain 5 in their name or IP address are displayed. Enter
a blank space to display all storage devices in the fabric.

d.

Click OK.

The server and storage device pair appears in the Access List.

Steps 5 and step 6 are optional.

5.

In the Access List, click the Modify icon

for the target entry to reselect the server or the storage

device.

6.

Click the Delete icon for the target entry if you want to reselect a pair of server and storage
device.

7.

Click the 2. Configuration Summary tab.
If the configuration meets the requirements for SAN fast configuration, VFM displays
configuration summary based on you configuration and automatic system configuration. If the

requirements are not met, VFM displays a tip to inform you of the incorrect settings.
Configuration summary includes:

{

Topology—The topology highlights the link between the server and the storage device.

{

Global Configuration

Fabric—Name of the fabric where the server and the storage device reside.

VLAN ID—VLAN ID used by the server-storage pair for mutual access. VFM automatically
selects the VLAN ID.

VSAN ID—VSAN ID restricted to the server-storage pair. VFM automatically selects the
VSAN ID.

Zone Set—Zone set to be activated in the VSAN. VFM automatically generates the zone set
name iMC_Zoneset. Zone set iMC_Zoneset contains a zone named iMC_Zone. The server

and the storage device are members of the zone.

Default Zone Policy—VFM automatically configures this parameter as Deny. Access
among members of the default zone is denied.

Zone Distribution Policy—VFM automatically configures this parameter as Only Active
Zone Set. VFM distributes only the active zone set to all FCoE switches in the VSAN.

{

Zone list contents

Zone Name—VFM automatically configures the zone name as iMC_Zone. iMC_Zone is the

only zone in zone set iMC_Zoneset.

Server—Name and IP address of the server in iMC_Zone.

Storage—Name and IP address of the storage device in iMC_Zone.

{

Device list contents
This list contains all FCoE switches in the VSAN.

Status—Alarm state of the FCoE switch in the IMC Platform. For more information about
alarm status, see H3C IMC Base Platform Administrator Guide.

Device Name—Name of the FCoE switch in the form of device label(IP address). The label
is the switch's label in the IMC Platform. The IP address is the switch's configured IP address
when it is imported to the IMC Platform.

{

Interface list contents
The list contains VFC interfaces on all FCoE switches in the VSAN.