Installation – Grass Valley NV7512 v.1.3 User Manual

Page 84

Advertising
background image

74

Rev 1.3 • 10 Oct 08

2. Installation

Making Alarm Connections

Figure 2-35. Alarm Connections and On/Off Switches

The following lists each DE9 pin and the associated alarm. The pin number listed corresponds to
the pin numbers in Figure 2-35 on page 74:

Typical Circuit 1

Customer-supplied relay

contacts NC, (but open during

alarm condition)

External Power,

30VDC max, 150mA max

Normally ON, the LEDs turn off to indicate failure

1

COM

Normally OFF, the LEDs turn on to indicate failure

30VDC max, 150mA max

External Power

1

1

2

3

4

5

6

7

8

9

1
2
3
4
5

Alarm COM
Alarm 1
Alarm 2
Alarm 3
Alarm 4

8
7
8
9

Alarm 5
Alarm 6
Alarm 7
Alarm COM

Typical Circuit 2

COM

Pin

Signal

Description

Possible Conditions Causing the Alarm

1 and
9

Alarm_COM

Common

Common connection for all alarm pins.

2

Alarm_1

Major Alarm

Indicates missing reference inputs, or missing
power supplies.

3

Alarm_2

Minor Alarm

Alarm_3, or Alarm_4, or Alarm_5, or Alarm_6

4

Alarm_3

Power Supply

Missing power supply module.

5

Alarm_4

Video Ref

Missing Video Ref 1 or Video Ref 2.

6

Alarm_5

AES Ref

Missing AES Ref 1 or AES Ref 2.

7

Alarm_6

Fans or

Temperature

Indicates a fan failure or module over temperature.

8

Alarm_7

Control Module
Health

Any control module not “healthy.”

Advertising
This manual is related to the following products: