Supported Objects 2-6

Yaskawa Output Instances

‹

Yaskawa Modbus Message – Output Instance 150 (96h)

‹

Yaskawa Standard Control – Output Instance 151 (97h)

Instance

Word

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

150 (96h)

MODBUS

Message

5 Bytes

0

0

Function Code

1

1

Register Number

1

2

3

Data

2

4

Note:

Refer to input instance 100 (64h) for command.

1

A Modbus message error is returned if the function code has the MSB (80h) set.

Instance

Word

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

151 (97h)
Standard

Control

8 Bytes

0

0

@Fault

@Alarm

@Ready

@Speed

Agree

@Fault

Reset

@REV

Run

@Zero

Speed

@FWD

Run

1

@Zero Servo

Complete

1

-

@Terminal

P2

2

@Terminal

P1

2

@Terminal

MA/MB

2

@Local

Mode

@ Pwr Loss

Ride Thru

@OPE

1

2

Output Frequency (Scaled by Parameter o1-03)

3

2

4

Torque Reference (0.1%) (FVC Mode Only) (A1-02 = 3)

5

3

6

Output Current (0.01A or 0.1A Based on Drive Capacity)

7

Note:

1

FVC mode only (A1-02 = 3)

2

G5 Byte 1

Bit 3 = Terminal 9

Bit 4 = Terminal 25

Bit 5 = Terminal 26