Supported objects 2-20 – Yaskawa CM012 DeviceNet Option Card User Manual
Page 41

Supported Objects 2-20
Class 104 (68h) - Yaskawa Application Parameter Object
Application Object – Class 104 (68h) Instance 1
Attr
G5M
F7U
G7U
P7U
Prm
Text
Prm
Text
Prm
Text
Prm
Text
1
b1-01
Ref Source
b1-01
Ref Source
b1-01
Ref Source
b1-01
Ref Source
2
b1-02
Run Source
b1-02
Run Source
b1-02
Run Source
b1-02
Run Source
3
b1-03
Stopping Method
b1-03
Stopping Method
b1-03
Stopping Method
b1-03
Stopping Method
4
b1-04
Rev Operation
b1-04
Rev Operation
b1-04
Rev Operation
b1-04
Rev Operation
5
b1-05
Zero Spd Operation
b1-05
Zero Spd Operation
b1-05
Zero Spd Operation
b1-05
Zero Spd Operation
6
b1-06
Control Input Scans
b1-06
Control Input Scans
b1-06
Control Input Scans
b1-06
Control Input Scans
7
b1-07
Local/Remote Run Select
b1-07
Local/Remote Run Select
b1-07
Local/Remote Run Select
b1-07
Local/Remote Run Select
8
b2-01
DC Inj Start Freq (Hz)
b1-08
Run Command @ Program
b1-08
Run Command @ Program
b1-08
Run Command @ Program
9
b2-02
DC Inj Current (%)
b1-09
Local/Remote Sel @ Drive
b1-09
Local/Remote Sel @ Drive
b1-09
Local/Remote Sel @ Drive
10 (Ah)
b2-03
DC Inj Time @ Start (s)
b2-01
DC Inj Start Freq (Hz)
b2-01
DC Inj Start Freq (Hz)
b2-01
DC Inj Start Freq (Hz)
11 (Bh)
b2-04
DC Inj Time @ Stop (s)
b2-02
DC Inj Current (%)
b2-02
DC Inj Current (%)
b2-02
DC Inj Current (%)
12 (Ch)
b2-05
DC Inj P Gain
b2-03
DC Inj Time @ Start (s)
b2-03
DC Inj Time @ Start (s)
b2-03
DC Inj Time @ Start (s)
13 (Dh)
b2-06
DC Inj I Time (s)
b2-04
DC Inj Time @ Stop (s)
b2-04
DC Inj Time @ Stop (s)
b2-04
DC Inj Time @ Stop (s)
14 (Eh)
b2-07
DC Inj Limit
b2-05
DC Inj P Gain
b2-05
DC Inj P Gain
b2-05
DC Inj P Gain
15 (Fh)
b3-01
Spd Srch Select
b2-06
DC Inj I Time (s)
b2-06
DC Inj I Time (s)
b2-06
DC Inj I Time (s)
16 (10h)
b3-02
Seed Srch Current (%)
b2-07
DC Inj Limit
b2-07
DC Inj Limit
b2-07
DC Inj Limit
17 (11h)
b3-03
Spd Srch Dec Time (s)
b2-08
Field Comp (%)
b2-08
Field Comp (%)
b2-08
Field Comp (%)
18 (12h)
b3-04
Spd Srch V/f
b3-01
Spd Srch @ Start
b3-01
Spd Srch @ Start
b3-01
Spd Srch @ Start
19 (13h)
b4-01
Delay ON Timer (s)
b3-02
Spd Srch Current (%)
b3-02
Spd Srch Current (%)
b3-02
Spd Srch Current (%)
20 (14h)
b4-02
Delay OFF Timer (s)
b3-03
Spd Srch Dec Time (s)
b3-03
Spd Srch Dec Time (s)
b3-03
Spd Srch Dec Time (s)
21 (15h)
b5-01
PID Mode
b3-04
Spd Srch V/f
b3-04
Spd Srch V/f
22 (16h)
b5-02
PID Gain
b3-05
Srch Delay Time (s)
b3-05
Srch Delay Time (s)
b3-05
Srch Delay Time (s)
23 (17h)
b5-03
PID I Time (s)
b3-06
Spd Srch Im Lvl 1
b3-06
Spd Srch Im Lvl 1
b3-06
Spd Srch Im Lvl 1
24 (18h)
b5-04
PID I Limit (%)
b3-07
Spd Srch Im Lvl 2
b3-07
Spd Srch Im Lvl 2
b3-07
Spd Srch Im Lvl 2
25 (19h)
b5-05
PID D Time (s)
b3-08
Spd Srch ACR P Gain
b3-08
Spd Srch ACR P Gain
b3-08
Spd Srch ACR P Gain
26 (1Ah)
b5-06
PID Limit (%)
b3-09
Spd Srch I Time (s)
b3-09
Spd Srch I Time (s)
b3-09
Spd Srch I Time (s)
27 (1Bh)
b5-07
PID Offset (%)
b3-10
Srch Detect Comp
b3-10
Srch Detect Comp
b3-10
Srch Detect Comp
28 (1Ch)
b5-08
PID Delay Time (s)
b3-11
Spd Srch Method
Switch Lvl
b3-11
Spd Srch Method
Switch Lvl
b3-11
Spd Srch Method
Switch Lvl
29 (1Dh)
b6-01
Dwell Freq @ Start (Hz)
b3-12
Spd Srch Deadband
b3-12
Spd Srch Deadband
b3-12
Spd Srch Deadband
30 (1Eh)
b6-02
Dwell Time @ Start (s)
b3-13
Spd Srch Est P Gain (%)
31 (1Fh)
b6-03
Dwell Freq @ Stop (Hz)
b3-14
Bi-directional Srch Select
b3-14
Bi-directional Srch Select
b3-14
Bi-directional Srch Select
32 (20h)
b6-04
Dwell Time @ Stop (s)
33 (21h)
b7-01
Droop Quantity (%)
34 (22h)
b7-02
Droop Delay Time (s)
35 (23h)
b8-01
Energy Save Gain (%)
36 (24h)
b8-02
Energy Save Freq (Hz)
b4-01
Delay ON Timer (s)
b4-01
Delay ON Timer (s)
b4-01
Delay ON Timer (s)
37 (25h)
b9-01
Zero Servo Gain
b4-02
Delay OFF Timer (s)
b4-02
Delay OFF Timer (s)
b4-02
Delay OFF Timer (s)
38 (26h)
b9-02
Zero Srvo Complet Width
b5-01
PID Mode
b5-01
PID Mode
b5-01
PID Mode
39 (27h)
b1-08
Run Cmd Sel @ Program
b5-02
PID Gain
b5-02
PID Gain
b5-02
PID Gain
40 (28h)
b5-09
PID Output Select
b5-03
PID I Time (s)
b5-03
PID I Time (s)
b5-03
PID I Time (s)
41 (29h)
b5-10
PID Output Gain
b5-04
PID I Limit (%)
b5-04
PID I Limit (%)
b5-04
PID I Limit (%)
42 (2Ah)
b5-11
PID Output Rev Select
b5-05
PID D Time (s)
b5-05
PID D Time (s)
43 (2Bh)
b1-09
Run Mode Change Sel
b5-06
PID Limit (%)
b5-06
PID Limit (%)
b5-06
PID Limit (%)
44 (2Ch)
b2-08
Field Comp @ Start
b5-07
PID Offset (%)
b5-07
PID Offset (%)
b5-07
PID Offset (%)
45 (2Dh)
b8-03
Energy Save Select
b5-08
PID Delay Time (s)
b5-08
PID Delay Time (s)
b5-08
PID Delay Time (s)
46 (2Eh)
b8-04
Energy Save Gain
b5-09
Output Lvl Select
b5-09
Output Lvl Select
b5-09
Output Lvl Select
47 (2Fh)
b8-05
Energy Save Time
b5-10
Output Gain
b5-10
Output Gain
b5-10
Output Gain