Operator programming errors (ope), Operator programming errors (ope) -12, Diagnostic & troubleshooting 6 - 12 – Yaskawa E7 Drive User Manual User Manual

Page 148

Advertising
background image

Diagnostic & Troubleshooting 6 - 12

Operator Programming Errors (OPE)

An Operator Programming Error (OPE) occurs when an inapplicable parameter is set or an individual parameter setting is
inappropriate.

The Drive does not operate until the parameter is set correctly. (Alarm output and fault contact do not operate.)

If an OPE occurs, change the appropriate parameter by checking the cause shown in Table 6.3.

Table 6.3 OPE Error and Fault Displays

Digital Operator

Display

Description

Cause

Corrective

Action

OPE01

kVA Selection t

Drive kVA setting error.

The control board was replaced and

the kVA parameter is set incorrectly

Enter the correct kVA setting (o2-04)
by referring to the Drive model

number in Appendix B

OPE02

Limit

Constant data out of range.

Parameter set above the allowable
range.

Verify the program settings

OPE03

Terminal

Multi-function input selection fault.

Duplicate functions are selected,

up/down commands or trim control
increase/decrease are not set

simultaneously. Speed search from

maximum frequency and set
frequency are set simultaneously.

Emergency override FWD (H1-0X
= 81) and Emergency Override

REV (H1-0X = 82) are set simulta-

neously.

Verify program settings
(H1-01~H1-05)

OPE05

Sequence Select

Run command is selected through

serial communication at 2CN but

option board is not installed.

Serial communication option board

is not installed, option board is

installed incorrectly. The run
command selection parameter

B1-02 is set to 3 and option board is

not installed.

Verify that the board is installed.

Remove power to the Drive and

connect the option board once more.

OPE09

PID Selection

PID Control Setup Error

The following settings have been

made at the same time:

b5-01 (PID Control Method Selec-
tion) has been set to a value other

than 0.

b5-15 (PID Sleep Function Start
Level) has been set to a value other

than 0.

b1-03 (Stopping Method Selection)
was set to 2 or 3.

Check parameters b5-01, b5-15, and

b1-03 and correct the error.

OPE10

V/f Ptrn Setting

V/f data setting fault

V/f parameter settings are not set
correctly.

Check parameters (E1-04 ~ E1-11).

A minimum frequency/voltage value
may be set higher than the maximum

frequency/voltage.

OPE11

CarrFrq/On-Delay

Carrier frequency data setting fault.
Carrier frequency proportional gain

C6-05 > 6 and C6-04 > C6-03.

Upper/lower limit error of C6-03 to
5.0kHz

Parameter setting incorrect.

Check the program settings and
correct the errors.

ERR

EEPROM R/W Err It does not match at EEPROM write.

• Power supply is turned OFF.

• Parameter is reset repeatedly.

• Cycle power off and on to Drive.

• Do a factory initialization (A1-03).

TM_E7_01_07182008.book Page 12 Wednesday, July 23, 2008 2:35 PM

Advertising
This manual is related to the following products: