480vac, Specifications c - 3 – Yaskawa E7 Drive User Manual User Manual

Page 207

Advertising
background image

Specifications C - 3

480VAC

Table C.1 480VAC Drive Specifications

Model Number CIMR-E7U

40P4

40P7

41P5

42P2

43P7

45P5

47P5

49P0

4011

4015

4018

Rated output capacity (kVA)

1.4

1.6

2.8

4.0

5.8

9.5

13.0

16.0

21.0

26.0

30.0

Motor HP (460V)

0.5/0.75

1

1.5/2

3

5

7.5

10

15

20

25

30

Rated output current (A)

1.8

2.1

3.7

5.3

7.6

12.5

17.0

21.0

27.0

34.0

40.0

Max. output voltage (V)

3-phase; 380, 400, 415, 440, 460, or 480VAC (Proportional to input voltage.)

Max. output frequency (Hz)

120 Hz

Rated voltage (V)
Rated frequency (Hz)

3-phase, 380, 400, 415, 440, 460 or 480VAC, 50/60 Hz

Rated input current (A)

2.2

2.5

4.4

6.4

9.0

15

20

26

33

40

48

Allowable voltage fluctuation

+ 10%, - 15%

Allowable frequency fluctuation

±5%

Measures for
power supply
harmonics

DC Reactor

Optional

12-pulse
Rectification

Not possible

Table C.1 480VAC Drive Specifications (Continued)

Model Number CIMR-E7U

4024

4030

4037

4045

4055

4075

4090

4110

4160

4185

4220

4300

Rated output capacity (kVA)

40.0

51.0

59.0

73.0

95.0

120.0

140.0

180.0

230.0

315.0

390.0

510.0

Motor HP (460V)

40

50

60

75

100

125

150

200

250

300/350 400/450

500+

Rated output current (A)

52.0

67.2

77.0

96.0

125.0

156.0

180.0

240.0

304.0

414.0

515.0

675.0

Max. output voltage (V)

3-phase, 380, 400, 415, 440, 460 or 480VAC (Proportional to input voltage)

Max. output frequency (Hz)

120 Hz

Max. voltage (V)
Rated frequency (Hz)

3-phase, 380, 400, 415, 440, 460, or 480VAC, 50/60 Hz

Rated input current (A)

57

74

85

106

134

172

198

264

334

456

567

743

Allowable voltage fluctuation

+ 10%, - 15%

Allowable frequency fluctuation

±5%

Measures for
power supply
harmonics

DC Reactor

Built-in

12-Pulse
Rectification

Possible

Note: The maximum applicable motor output is given for a standard 4-pole motor. When selecting the actual motor and Drive, be sure that the Drive's rated

output current is applicable for the motor's rated current.
A 3-wire phase-shifting transformer is required on the power supply for 12-pulse rectification.

Ou

tput r

atings

P

owe

r s

upp

ly

ch

ar

ac

te

ri

stic

s

Cont

ro

l char

act

er

is

tic

s

Outp

ut r

atings

Power

su

pply c

ha

racter

is

tics

Cont

ro

l char

act

er

is

ti

cs

TM_E7_01_07182008.book Page 3 Wednesday, July 23, 2008 2:35 PM

Advertising
This manual is related to the following products: