Diagnostic & Troubleshooting 6 - 13

Auto-Tuning Faults

Auto-tuning faults are shown below. When the following faults are detected, the fault is displayed on the digital operator and
the motor coasts to a stop during operation. The fault contact is not activated.

Table 6.4 Auto-Tuning Displays and Processing

Digital Operator Display

Probable Cause

Corrective Action

Er - 01

Fault

•There is an error in the data input
for autotuning.
•There is an error in the relationship
between the motor output and the
motor rated current.

• Check input data.

• Check Drive and motor capacity.

• Check motor rated current.

Er - 02

Minor Fault

A minor fault is detected during

auto-tuning.

• Check input data.

• Check wirings and around the

machine.

• Check the load.

Er - 03

STOP key

The STOP key is pressed during

auto-tuning, and the auto-tuning is

interrupted.

Er - 04

Resistance

Auto-tuning is not completed within

the specified time.

The auto-tuning result became other

than the parameter set range.

• Check input data.

• Check motor wiring.

• If a motor and a machine are

connected, disconnect the motor

from the machine.

Er - 12

I-det. Circuit

•Current flow exceeded the motor

rated current.

•Current detection value symbol was

reversed.

•Any of U/TI, V/T2, and W/T3 has

open-phase.

• Check current detection circuit,

wiring and mounting procedure.

Er - 13

Leakage Inductance Fault

Auto-tuning did not finish within the
set time.
Tuning result became other than the
parameter setting range.

• Check motor wiring.

End - 3

Data Invalid

Rated current set value is set too
high.

• Check input data (especially, motor

output current and motor rated cur-
rent value).

TM_E7_01_07182008.book Page 13 Wednesday, July 23, 2008 2:35 PM